Prüfprotokoll #3

S/N HA1012 003133 — 2026-08-25

RH20 Head Inspection Report

Head Model
RH20
Seriennummer
HA1012 003133
Datum
2026-08-25
Techniker
Marc Backes

1. Internal Head Sensor — einmalige Messung je Kopf

Parameter Standard Messwert Ergebnis
Contact Detection — Pressure 70 ± 4 kPa 70 PASS
Internal Head Sensor — Flow Rate ≥ 3.5 L/min 5.3 PASS

Messwerte je Shaft (A–T)

Shaft Internal Head Sensor Vacuum — Z1 Vacuum — Z2 Vacuum Break Down Nozzle Cleaning Valve Air Stick Overall
Pressure (kPa)
A: 65 ± 2.5 · B–T: 65 ± 10
Pressure (kPa)
|Wert| ≥ 80
Flow (L/min)
≥ 2.0
Pressure (kPa)
|Wert| ≥ 80
Flow (L/min)
≥ 2.0
Pressure (kPa)
10 – 15
Flow (L/min)
≥ 0.5
Pressure (kPa)
≥ 100
Flow (L/min)
≥ 0.8
Repeated Sliding (mm)
|Wert| ≤ 0.08
A 64.71 91 3.5 90 3.5 12 3.1 100 6.5 — —
B 65.69 89 3.4 89 3.6 13 3.2 100 6.5 — —
C 64.71 89 3.6 89 3.5 13 3.2 100 6.7 — —
D 62.75 89 3.6 89 3.6 13 3.2 100 6.7 — —
E 66.67 90 3.5 90 3.6 13 3.2 100 9.8 — —
F 64.71 90 3.5 90 3.6 12 3.2 100 6.7 — —
G 65.69 90 3.4 90 3.5 13 3.2 100 6.7 — —
H 65.69 91 3.6 90 3.6 14 3.2 100 6.8 — —
I 64.71 91 3.5 90 3.5 13 3.2 100 6.7 — —
J 64.71 91 3.4 91 3.5 14 3.2 100 6.6 — —
K 64.71 90 3.6 90 3.6 13 3.2 100 6.7 — —
L 62.75 91 3.5 90 3.6 13 3.3 100 6.8 — —
M 64.71 92 3.5 91 3.6 13 3.2 100 6.7 — —
N 64.71 90 3.5 90 3.5 13 3.2 100 6.7 — —
O 65.69 90 3.4 90 3.6 13 3.2 100 6.8 — —
P 64.71 90 3.6 89 3.5 13 3.2 100 6.8 — —
Q 62.75 90 3.5 90 3.5 13 3.1 100 6.8 — —
R 64.71 89 3.5 88 3.6 13 3 100 6.9 — —
S 64.71 90 3.6 90 3.6 13 3 100 6.8 — —
T 65.69 89 3.5 89 3.5 13 3 100 6.8 — —
Innerhalb der Spezifikation Grenzwertig — zulässig, aber auffällig Außerhalb der Spezifikation — kein Messwert erfasst

Zusammenfassung

INCOMPLETE20 von 20 Shafts noch nicht vollständig erfasst
  • 0 PASS
  • 0 grenzwertig
  • 0 FAIL
  • 20 ausstehend
20 Shafts gesamt (A–T)